100W High Voltage Power Supply Connections
7705 SAR-A Chassis Installation Guide 91
Note:
1. Two AC cord sets are supplied with the 100W High Voltage Power Supply to match North American and
European style AC outlets. Both cord sets have an IEC 320 C13 female connector (plug) at one end.
Wiring and Connecting AC Power via the 100W High
Voltage Power Supply
Required tools and hardware:
one 100W High Voltage Power Supply (two are required for redundant power
configurations)
wire stripper
torque driver for slot screws; No. 2 slotted blade width, 0.125 in (3.2 mm)
Follow these steps to wire and connect an AC power supply to the –48 VDC power feed
inputs on the 7705 SAR-A terminal block via the 100W High Voltage Power Supply.
Figure 20 shows the terminal connections; Table 23 identifies the key items in the figure.
Step 1. Prepare the open-ended DC output wire from the 100W High Voltage Power
Supply by stripping 0.35 in. (9 mm) of insulation from each power cable at the
router end, as shown in Figure 21. Table 24 identifies the key items in the figure.
Figure 21: DC Power Cable
Table 23: Connecting the 100W High Voltage Power Supply to the 7705 SAR-A
Key Description
1 0.35 in. (9 mm) of outer shielding removed from each wire to expose the
conductor
2 100W High Voltage Power Supply
3
Single-feed high voltage AC or DC input (IEC 320-C14 connector)
1
2
1
23318