100W High Voltage Power Supply Connections
7705 SAR-A Chassis Installation Guide 93
Step 2. Insert the –VDC black wire from the 100W High Voltage Power Supply into the
–Batt wire receptacle on the 7705 SAR-A. Tighten the screw to a torque of 
3.54 to 4.42 lbf-in (0.4 to 0.5 N
.
m) maximum.
Step 3. Insert the +VDC red wire from the 100W High Voltage Power Supply into the
+Batt wire receptacle on the 7705 SAR-A. Tighten the screw to a torque of 
3.54 to 4.42 lbf-in (0.4 to 0.5 N
.
m) maximum.
Step 4. For redundant power supply configurations, repeat steps 1 to 3.
Step 5. Prepare the power input end of the power supply cord set by cutting off the AC 
connector (male plug) from the North American or 240V European power cord.
Step 6. Expose and strip an appropriate length of the insulated outer jacket from the wires 
in the cut end of the power cord.
Step 7. Connect the wires:
i. Attach the green or green/yellow wire to the building earth.
ii. Attach the black or brown wire to one DC terminal on the power source.
iii. Attach the white or blue wire to the other DC terminal on the power source.
Step 8. Connect the IEC connector on the modified North American or 240V European 
power cord to the IEC connector on the 100W High Voltage Power Supply.