Chassis and Power Supplies OmniSwitch 6560 Chassis Details
OmniSwitch 6560 Hardware Users Guide December 2019 page 3-9
OS6560-P48X4 Chassis Specifications
*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of 
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room 
temperature. The ambient temperature will typically be lower than the chassis temperature. 
Chassis Height 4.4 cm (1.73 in)
Chassis Width  44 cm (17.33 in)
Chassis Depth  35 cm (13.78 in)
Chassis Weight (no power supplies) 4.63 kg (10.20 lb) 
Power Consumption (idle) 107 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 95% non-condensing