Monitoring Chassis Components Chassis and Power Supplies
page 3-44 OmniSwitch 6560 Hardware Users Guide December 2019
Monitoring Chassis Components
Viewing Chassis Slot Information
To view basic slot information, enter the show module command at the CLI prompt:
-> show module
To view more detailed information, use the show module long command:
-> show module long
Monitoring Chassis Temperature
The operating temperature of your switch is a critical factor in its overall operability. In order to avoid a
temperature-related system failure, your switch must always run at a temperature within the specified
operating temperature range.
To avoid chassis over-temperature conditions, follow the important chassis airflow recommendations on
page 3-25.
To check the switch’s current temperature status, use the show temperature command. For example:
-> show temperature
Chassis/Device | Current | Range | Danger | Thresh | Status
---------------+---------+---------+--------+--------+-----------------
1/CMMA 54 15-93 93 96 UNDER THRESHOLD
1/Slot1 54 15-93 93 101 UNDER THRESHOLD
2/CMMA 39 15-85 85 88 UNDER THRESHOLD
2/Slot1 39 15-85 85 101 UNDER THRESHOLD
For more information about this command, see the “Chassis Management and Monitoring Commands”
chapter in the OmniSwitch CLI Reference Guide.