Configuring the Switch
120
3
Defining RMON History Control
The History Control Page contains information about samples of data taken from
ports. For example, the samples may include interface definitions or polling periods.
Command Attributes
• History Entry No. — Displays the entry number for the History Control Table page.
• Source Interface — Displays the interface from which the history samples were
taken. The possible field values are:
• Port — Specifies the port from which the RMON information was taken.
• LAG — Specifies the port from which the RMON information was taken.
• Sampling Interval — Indicates in seconds the time that samplings are taken from
the ports. The field range is 1-3600. The default is 1800 seconds (equal to 30
minutes).
• Samples Requested— Displays the number of samples to be saved. The field
range is 1-65535. The default value is 50.
• Current Number of Samples — Displays the current number of samples taken.
• Owner — Displays the RMON station or user that requested the RMON
information. The field range is 0-20 characters.
• Remove — Removes History Control entries. The possible field values are:
• Checked — Removes the selected History Control entry.
• Unchecked — Maintains the current History Control entries.
Web – Click System, RMON, History, History Control and select an interface.
Undersize Pkts: 0 Oversize Pkts: 0
Fragments: 0 Jabbers: 0
64 Octets: 98 65 to 127 Octets: 0
128 to 255 Octets: 0 256 to 511 Octets: 0
512 to 1023 Octets: 491 1024 to 1518 Octets: 389