EasyManua.ls Logo

Allen-Bradley ControlLogix - Page 157

Allen-Bradley ControlLogix
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interpret the Attribute Tables
Chapter 3
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018 157
ID Access Rule Attribute Name B E F P V T Conditional Implementation
730 Get Digital Inputs
- N N N N
731 Set Digital Outputs
- N N N N
1435 Set Feedback 1 Accel Filter Bandwidth
Y - Y Y Y
2404 Set Feedback 1 Accel Filter Taps
Y - Y Y Y
2405 Set Feedback 1 Battery Absolute
N - N N N TM
1421 Set Feedback 1 Data Code
N - N N N TP,SS
1420 Set Feedback 1 Data Length
N - N N N TP,SS
2400 Set Feedback 1 Loss Action
N - N N N O-Enum
1 = Switch to Sensorless Fdbk (N)
2 = Switch to Redundant Fdbk (N)
1414 Set Feedback 1 Polarity
Y - Y Y Y
1425 Set Feedback 1 Resolver Cable Balance
N - N N N RS
1424 Set Feedback 1 Resolver Excitation Frequency
N - N N N RS
1423 Set Feedback 1 Resolver Excitation Voltage
N - N N N RS
1422 Set Feedback 1 Resolver Transformer Ratio
N - N N N RS
1401 Get Feedback 1 Serial Number
Y - Y Y Y
1415 Set Feedback 1 Startup Method
R - R R R O-Enum
1 = Absolute (Y)
1434 Set Feedback 1 Velocity Filter Bandwidth
Y - Y Y Y
2403 Set Feedback 1 Velocity Filter Taps
Y - Y Y Y
1485 Set Feedback 2 Accel Filter Bandwidth
Y - Y Y Y
2454 Set Feedback 2 Accel Filter Taps
Y - Y Y Y
2455 Set Feedback 2 Battery Absolute
N - N N N TM
1471 Set Feedback 2 Data Code
N - N N N TP,SS
1470 Set Feedback 2 Data Length
N - N N N TP,SS
2450 Set Feedback 2 Loss Action
N - N N N O-Enum
1 = Switch to Sensorless Fdbk (N)
2 = Switch to Redundant Fdbk (N)
1464 Set Feedback 2 Polarity
Y - Y Y Y
1475 Set Feedback 2 Resolver Cable Balance
N - N N N RS
1474 Set Feedback 2 Resolver Excitation Frequency
N - N N N RS
1473 Set Feedback 2 Resolver Excitation Voltage
N - N N N RS
1472 Set Feedback 2 Resolver Transformer Ratio
N - N N N RS
1451 Get Feedback 2 Serial Number
Y - Y Y Y
1465 Set Feedback 2 Startup Method
R - R R R O-Enum
1 = Absolute (Y)
1484 Set Feedback 2 Velocity Filter Bandwidth
Y - Y Y Y
2453 Set Feedback 2 Velocity Filter Taps
Y - Y Y Y
250 Set Feedback Commutation Aligned
- - Y Y Y O-Enum
2 = Motor Offset (Y)
3 = Self-Sense (Y)

Table of Contents

Other manuals for Allen-Bradley ControlLogix