206Alvium USB Cameras User Guide V4.6.1
Specifications
Closed housing 180°
Closed housing 90°
Closed housing C-Mount CS-Mount S-Mount
Flange focal distance, optical 17.526 mm 12.526 mm 12.63 mm
Thread 1“-32tpi UNS-2B 1“-32tpi UNS-2B M12 × 0.5 mm
Maximum protrusion
1
13.6 mm
8.6 mm
11.0 mm
Body dimensions (L × W × H) in [mm] 38 × 29 × 29 33 × 29 × 29 33 × 29 × 29
Mass
2
60 g
Mass
3
65 g
1
For details, see Maximum protrusion for front mounts.
2
Alvium 1800 U-040, -050, -120, -131, -192, -234, -235, -319, -500, -501, -507, -507 Pol
3
Alvium 1800 U-030, -052, -130, -158, -203,-240, -291, -320 VSWIR, -508, -508 Pol, -510, -511,
-520 VSWIR, -811, 812, -895, -1236, -1240,-1242, -1620, -2040, -2050, -2460
Table 98: Standard Alvium - closed housing 180° dimensions and mass
USB 90° Closed housing C-Mount CS-Mount S-Mount
Flange focal distance, optical 17.526 mm 12.526 mm 12.63 mm
Thread 1“-32tpi UNS-2B 1“-32tpi UNS-2B M12 × 0.5 mm
Maximum protrusion
1
13.6 mm
8.6 mm
11.0 mm
Body dimensions (L × W × H) in [mm] 38 × 32 × 29 33 × 32 × 29 33 × 32 × 29
Mass
2
65 g
Mass
3
70 g
1
For details, see Maximum protrusion for front mounts.
2
Alvium 1800 U-040, -050, -120, -131, -192, -234, -235, -319, -500, -501, -507, -507 Pol
3
Alvium 1800 U-030, -052, -130, -158, -203,-240, -291, -320 VSWIR, -508, -508 Pol, -510, -511,
-520 VSWIR, -811, 812, -895, -1236, -1240,-1242, -1620, -2040, -2050, -2460
Table 99: Standard Alvium - closed housing 90° dimensions and mass