233Alvium USB Cameras User Guide V4.6.1
Specifications
Housed Alvium Frame: Sensor shift and
rotation
The following table defines the manufacturing accuracy for sensor positioning with
housed Alvium Frame cameras. For sensor tilt, see Housed Alvium USB cameras:
Sensor tilt on page 233.
Housed Alvium USB cameras: Sensor tilt
The following table defines sensor tilt as the variance between highest and lowest
pixel of a sensor along the z-axis, measured in micrometers for housed Alvium USB
cameras.
Values for Alvium Frame cameras
For sensor shift and rotation with Alvium Frame cameras, see Housed Alvium
Frame: Sensor shift and rotation on page 233. For sensor tilt, see Housed Alvium
USB cameras: Sensor tilt on page 233.
Criteria Subject Properties
Alignment method Optical alignment of the photosensitive sensor area into the camera
front module (lens mount front flange)
Reference Points Sensor Center of the pixel area (photo sensitive cells)
Camera Center of the lens mount
Accuracy x/y-axis ±90 µm (sensor shift)
z 0 to -50 µm (optical back focal length)
α
1
±0.5 deg
(sensor rotation as the deviation from the parallel to the
camera bottom)
Table 108: Alvium USB Frame cameras, sensor shift and rotation
Figure 81: Sensor tilt
Alvium model Pixel size Maximum tilt
Alvium 1800 U-030 VSWIR 5 µm × 5 µm 50 µm
Alvium 1800 U-040m/c 6.9 µm × 6.9 µm 95 µm
Table 109: Sensor tilt (sheet 1 of 2)