95Alvium USB Cameras User Guide V4.6.1
Specifications
Absolute QE
1800 U-130 VSWIR
Storage temperature -20 °C to +85 °C ambient temperature
Operating temperature
Hardware
option
Housing
Cooling area
1
Mainboard
2
Bare board
3
Not applicable
-20 °C to +85 °C
-20 °C to +85 °C
Open housing
4
-20 °C to +65 °C
Closed housing -20 °C to +65 °C Not applicable
Relative humidity 0% to 80% (non-condensing)
Digital interface Micro-B USB 3.1 Gen 1 interface
Camera controls GenICam (GenICam Access)
1
See Mounting the heat sink on page 259.
2
Output by DeviceTemperature
3
Ensure that the sensor is operated in the temperature range specified by the manufacturer. For any
questions, please visit www.alliedvision.com/en/support.
4
Temperature values must be observed for the housing and for the cooling area.
Figure 17: Alvium 1800 U-130 VSWIR (Sony IMX990) absolute QE
Feature Specification
Table 30: Alvium 1800 U-130 VSWIR specifications (sheet 2 of 2)
0%
10%
20%
30%
40%
50%
60%
70%
80%
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
Quantum Eĸciency [%]
Wavelength [nm]
Sony IMX990, IMX991 absolute QE