EasyManua.ls Logo

Allied Vision Alvium Series - About S-Mount lenses; Focal length vs. field of view; Alvium 1800 U-030 VSWIR

Allied Vision Alvium Series
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
241Alvium USB Cameras User Guide V4.6.1
Lenses: Focal length vs. field of view
About S-Mount lenses
Alvium S-Mount models have no filter. For typical applications, we recommend
using S-Mount lenses with an integrated IR cut filter for a better image quality.
Read Mounting and focusing S-Mount lenses on page 266 to avoid damage when
using S-Mount lenses.
Focal length vs. field of view
Alvium 1800 U-030 VSWIR
Values for 1800 U-030 VSWIR cameras with Type 1/4 (4.1 mm diagonal) sensors:
Focal length [mm]
Field of view (H × V [mm])
Object distance = 500 mm Object distance = 1000 mm
4 407 × 322 817 × 647
5 775 × 773 1557 × 1553
6 644 × 642 1296 × 1293
8 481 × 480 970 × 968
12 318 × 317 644 × 642
16 237 × 236 481 × 480
25 149 × 148 305 × 304
35 104 × 104 216 × 215
50 70 × 70 149 × 148
Table 113: Focal length versus field of view for Alvium 1800 U-030 VSWIR

Table of Contents

Other manuals for Allied Vision Alvium Series

Related product manuals