5000KIT | 5000KIT AUTOMATION SET 85
TESTING AND COMMISSIONING
SETTING
INDICATION
SETTING DETAILS
Programming remote controls
To record a remote control in the receiver memory, open the menu and select a record number
without a point after the digits (e.g., —record number is free), then press the selected
remote-control button. The display indication will ash several times, and the number with a point
will light up ( —the remote control is recorded). The maximum number of recorded remote
controls is 60. The operating range of a remote control in the open is not less than 50 metres.
To nd a remote-control record number (if the remote control is already recorded) or to nd out
whether a remote control is recorded or not, press any button on the remote control when in the
‘ ’ setting mode. If the remote control is recorded, the remote-control number with a
point shown after the digits, will light up on the display. If the remote control is not recorded,
the ‘ ’ indication on the display will just ash several times.
To reassign (rerecord) another remote-control button in the ‘ ’ settings, nd the remote-
control record number and press another remote-control button. The number with a point
after the digits will ash several times on the display, which will mean the remote-control
button is rerecorded.
To delete a remote control, select the remote-control record number in the ‘ ’ setting
mode, then press the ‘CL’ button on the control unit module and hold it for not less than
3 seconds. After that, the display indication will ash several times, and the number without
a point after the digits will light up.
To delete all the remote controls, press and hold the ‘CL’ button on the control unit module
for 3 seconds when in the ‘ ’ setting mode. The display indication will ash several times,
which will mean all the remote controls are deleted from the module memory.
8. TESTING AND COMMISSIONING
8.1 TESTING
After the product has been mounted, connected, and set up, it is necessary to perform a num-
ber of actions to test whether the drive system is operating properly. Each accessory requires
a separate testing method. It is advisable to complete all the procedures as indicated in the
corresponding operation manuals.
The testing is performed as follows:
• make sure that the full scope of the instructions in section 1. ‘General warnings and safety rules’
and other requirements of the manual are complied with.
• Make sure that the drive is stable, reliable, and can sustain loads, even if the gate stops or
accelerates suddenly. All the removed covers as well as drive and control unit components are
in place.
• Release the drive. Manually open and close the gate several times. Check that there are no
points of increased resistance to movement, there are no assembly and setup defects, and
the mounting dimensions are as appropriate. Make sure that, when the gate is closed and
opened manually, the leaves can be moved with a force not exceeding 225 N (~ 23 kg)—for
residential / private properties, and not exceeding 390 N (~ 40 kg)—for industrial / commercial
facilities. Return the drive to the engaged state.
• Complete several ‘open-close’ cycles. Make sure, that the gate moves in the required directions
and stops in the required final positions, and the leaves move smoothly. Check whether the
connected control devices operate properly. Test the operation of the electric lock, if one is
fitted.
• Check the correct operation of each connected safety and alarm device (a motion stop device,
photocells, lamps, etc.).