EasyManua.ls Logo

Ametek 2003RP - Figure 3-6: Input and Output Wiring; Table 3-1: Maximum Output Wiring Lengths

Ametek 2003RP
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output Current
Wire Size
Maximum wire length from output to load, 1% drop
5.0 A
RMS
0.75 mm
2
6 m 20 ft
5.0 A
RMS
AWG 18
6.4 m 21 ft
5.0 A
RMS
1.0 mm
2
8 m 26 ft
5.0 A
RMS
AWG 16
8.5 m 28 ft
5.0 A
RMS
1.5 mm
2
12 m 39 ft
5.0 A
RMS
AWG 14
14 m 45 ft
Table 3-1: Maximum Output Wiring Lengths
The Remote Sense inputs must be connected or an output voltage 7% higher than the
programmed output will be generated. If the 2003RP is configured for constant voltage, a
fault will be generated.
L
N
GND
Ferrite
L N Gnd
AC Input
Safety Cover
AC
Input
HI LO
AC
Output
Ferrite
Clamp
AC Output
Safety Cover
Figure 3-6: Input and Output Wiring

Table of Contents