Appendix B – Telnet (Terminal) Commands
118
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Telnet Commands (continued)
SET TELNET PORT Sets the device’s IP port listened to for Telnet connections.
Example:
>SET TELNET PORT
Current telnet port number = 23
Enter new telnet port number (Usually 23)(0 = disable Telnet):
Once you enter a value and press the Enter key, you get the following message:
Setting telnet port number to 23
New telnet port number set, reboot the device for the change to take
effect.
Note: This command requires a reboot to enable new settings.
SET TELNET
USERNAME
Note: This command is supported but is not presently in the Help file list of
commands.
Sets the Username for a secure Telnet session.
Default = blank (no username required)
For details, see page 112.
SET TELNET
PASSWORD
Note: This command is supported but is not presently in the Help file list of
commands.
Sets the Password for a secure Telnet session.
Default = blank (no password required)
For details, see page 112.
SHOW CONNECTION
LOG
Shows the Master connection log for the device.
SHOW CONNECTION
STATS
Shows the connection statistics for the device.
Output similar to the following example:
>show connection stats
Connection Statistics
Total Last 15 Minutes
===== ===============
ICSP Messages: 10039 received 333 received
10038 transmitted 333 transmitted
Blink Messages: 5014 received 166 received
IP Statistics:
RX packets:29298 errors:0 discarded:0
TX packets:15286 errors:0 discarded:0
SHOW LOG Displays the message log.
Syntax:
SHOW LOG <start>
Use <start> to specify the message number to start displaying.
Use <all> to display all messages.
SHOW VS100 STATS Displays DXLink transport information.

Table of Contents

Other manuals for AMX DXLink

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX DXLink and is the answer not in the manual?

AMX DXLink Specifications

General IconGeneral
CategoryReceiver
DimensionsVaries by model
WeightVaries by model
HDCP ComplianceYes
Video Input SignalHDMI
ControlRS-232, IR, Ethernet
Input ConnectorHDMI
Output ConnectorHDMI
Operating Temperature0° to 50° C
Humidity10% to 90% non-condensing
Storage Temperature-20° to 70° C

Related product manuals