Appendix B: Backward Compatibility 70 (114)
B.11.4 Network Configuration Object (04h)
The following attributes are removed in the 40–series. The Anybus CompactCom will never
request these attributes. It is only possible to set these values via the network (I&M1-4) – end
user configuration.
• Instance #3, Function Tag
• Instance #4, Location Tag
• Instance #5, Installation Date
• Instance #6, Description
B.11.5 GSD file (PROFIBUS configuration file used by engineering tool)
Implementation Type If the keyword “Implementation Type” is present in the GSD-file (optional keyword),
the value for the 30-series shall be “NP30” and the value for the 40-series shall be
“NP40”.
Length Related
Keywords
The following keywords are possible to set to maximum values if neeed in the 40-
series. In the 30-series the maximum lengths were dependent of the buffer mode
setting.
• Max_Input_Len
• Max_Output_Len
• Max_Data_Len
• Max_User_Prm_Data_Len
• Max_Diag_Data_Len
Anybus
®
CompactCom
™
M40 Hardware Design Guide HMSI-216-126 EN 2.6