30
16 MAINTENANCE / DIAGNOSTICS / REPAIRS
• Clean only with a soft wet cloth.
• Do not use aggressive detergents or products.
• Do not clean equipment with direct water jets.
16.1 Error messages
In case of error, the BLC system is deactivated: the control automatically switches to MANUAL mode.
Solve the problem, then reactivate the AUTOMATIC mode (par. 15.2).
Fig. 76
Check sensors
In case of errors, VISIO shows an appropriate alarm message.
Press
OK to consult the list of alarms and sensors.
ERROR MESSAGE CAUSE SOLUTION
Sens. 1: Not connected
Sens. 2: Not connected
Sens. 3: Not connected
Sens. 4: Not connected
Sensor not connected. Check connections on the relevant connecting cable.
IBX conn.Lost! / BLC conn.Lost! IBX100 not connected.
Check connections on connecting cables
3 and 4 (par. 8.3).
Boot error! / BLC conn.Lost! IBX100 not connected upon start.
Check connections on connecting cables
3 and 4 (par. 8.3).
16.2 Troubleshooting
PROBLEM CAUSE SOLUTION
VISIO is off or does not switch on
No power supply Check power supply connection
Device is OFF Press the ON key
VISIO shows wrong data
Wrong setup Check displayed data setup
Sensor fault
Contact the nearest Assistance Center
VISIO fault
16.3 Data and units of measurement shown - Setup menu
Menu Data Min. Max. UOM DEFAULT Other values that can be set / Notes
BLC settings
Basic settings
Number of sensors 2 4 no. 2
Wizard
External sens. [X]
-100.00 100.00 m 10.00 m
-330.00 330.00 ft 32.81 ft
External sens. [Y]
-100.00 100.00 m 00.00 m
-330.00 330.00 ft 0.00 ft
Internal sens. [X]
-100.00 100.00 m 5.00 m
-330.00 330.00 ft 16.40 ft
Internal sens. [Y]
-100.00 100.00 m 00.00 m
-330.00 330.00 ft 0.00 ft
HL Button -- -- -- External Keyboard
Boom settings
Boom geometry
Actuators
Boom width
0.01 1000.00 m 24.00 m --
0.01 3300.00 ft 78.74 ft --
Adjustment parameters
Height ctrl aggr. 0.0 100.0 -- 10.0 --
Tilt. ctrl aggress. 0.0 100.0 -- 2.0 --
Height error gain 0.0 9999.9 -- 10.0 --
Tilt. speed damping 0.0 9999.9 -- 10.0 --
Funct. Definition Headland detection -- -- -- HL Button/Height OFF - HL Button - “Height” Switch
Options
Language -- -- -- English
Česky - Deutsch - English - Español - Français -
Magyar - Italiano - Polski - Português - Русский
Unit of measurement
Speed -- -- -- m/s ft/s
Length -- -- -- m ft
Height -- -- -- cm in
Angle -- -- -- ° rad
Display contrast 0 100 % 50% --
Alarm tones -- -- -- ON OFF
Keytones -- -- -- ON OFF
User access -- -- -- Technician Operator - Manager - ARAGTech
Operating mode -- -- --
Only BLC
Only TTC
BLC and TTC
--
MAINTENANCE / DIAGNOSTICS / REPAIRS