115
ARCHTTP PROXY SERVER INSTALLATION
Complete Init Warning Volume initialization completed
Complete Rebuild Warning Volume rebuilding completed
Complete Migrate Warning Volume migration completed
Complete Check Warning Volume parity checking completed
Create Volume Warning New Volume Created
Delete Volume Warning Volume deleted
Modify Volume Warning Volume Modied
Volume Degraded Urgent Volume degraded Replace HDD
Volume Failed Urgent Volume failure
Failed Volume
Revived
Urgent Failed Volume revived
C. RaidSet Event
Event Level Meaning Action
Create RaidSet Warning New Raidset created
Delete RaidSet Warning Raidset deleted
Expand RaidSet Warning Raidset expanded
Rebuild RaidSet Warning Raidset rebuilding
RaidSet
Degraded
Urgent Raidset degraded Replace HDD
D. Hardware Event
Event Level Meaning Action
DRAM 1-Bit ECC Urgent DRAM 1-Bit ECC
error.
Check DRAM
DRAM Fatal Error Urgent DRAM fatal error
encountered.
Check the DRAM module
and replace with new one if
required.
Raid Powered On Warning Raid Power On
Test Event Urgent Test Event
Note:
It depends on models, not every model will encounter all events.