PRELIMINARY
USER MANUAL
Ascom i63 VoWiFi Handset
Alarm Operation
The Man-down alarm reacts if the handset is tilted (default 45°) from the vertical for a predefined period of
time (default 7 s). The No-movement alarm will react if no movement is detected during a predefined period
of time (default 30 s).
The handset alerts by beep and vibrator signals, depending on the settings, during a predefined period of
time (default 7 s). At the same time, the handset displays the message Man-down warning. Cancel? or
No-movement warning. Cancel?.
The handset then sends the alarm, unless the alarm is cancelled. The handset confirms that the alarm has
been sent by beep or vibrator signals. In addition, the handset displays the message Man-down warning
sent or No-movement warning sent.
The handset location is sent along with the alarm, see 6.5 Alarm with Additional Information, page 45.
If configured in the Device Manager, an Acoustic Location Signal (ALS) is activated after the alarm has been
sent, see 6.6 Automatic Call after Alarm, page 45.
The handset can be programmed to automatically call a predefined telephone number after the alarm has
been sent, see 6.6 Automatic Call after Alarm, page 45.
The Man-down and No-movement alarm functions are inactive under the following conditions:
While the handset is placed in a charger.
During calls (depending on settings), to avoid false alarms if the user tilts the handset, or is motionless
during a call.
For a predefined period of time (default 10 min) if the Mute button is pressed during the alert signal.
Activate/Deactivate the Man-down and/or No-movement Alarm
1 Enter Settings, and step to Alarm.
2 Select the wanted alarm(s) and press Back repeatedly.
The corresponding icon(s) appear on the display.
3 Follow the same steps to deactivate the alarm(s).
Cancel Man-down and No-movement Alarm
1 Press the soft key OK to confirm Man-down warning.
Cancel? or No-movement warning. Cancel?,
which appears in the display during the alert signal or
press any key.
Delay Man-down and No-movement Alarm Temporarily
1 Press the Mute button during the alert signal and then
press Yes to confirm the message Delay MD/NM
detection?.
The corresponding display icon flashes until the alarm
is active again (default 10 min).
TD 93289EN / / Ver.
44

Table of Contents

Other manuals for ASCOM i63

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASCOM i63 and is the answer not in the manual?

ASCOM i63 Specifications

General IconGeneral
Display TypeTFT, 256K colors
BatteryRemovable Li-Ion 800 mAh battery
Internal Memory64 MB
TechnologyGSM
Display Size2.2 inches
Resolution240 x 320 pixels
NetworkGSM 900 / 1800 / 1900
External MemorymicroSD
BluetoothYes
USBYes

Related product manuals