Testing Your System
Digital Life User Manual | Page 54 of 62 ATT-UM-V1.1-201303
Device Procedure Results Notes
End-to-End Testing
Test each device one at
a time by executing the
following procedure:
o Arm the system in
the Armed-AWAY
Mode
o Walk in front of one
motion detector
o After alarm has
been observed,
enter your Alarm
Panel PIN to cancel
the alarm and then
enter your Alarm
Panel PIN again to
clear the message
Keypad LCD will display:
<PIR Device Name> -
Motion (For example,
“Great Room - Motion”)
Keypad LCD will display:
Intrusion Alarm Sent
Keypad LCD will
Display: Alarm – Enter
PIN to Cancel
Keypad LCD will display:
Alarm Canceled
Keypad LCD will display:
Enter PIN to Clear
activations of
motion detector,
which is done to
preserve battery
life
An Intrusion alarm
has been sent to
AT&T Digital Life
Central Monitoring
Center with no
action required
CO Detector
(SW-ATT-CO)
DLS in
Test/Maintenance
Mode
End-to-End Testing
Test each device one at
a time by executing the
following procedure:
o Make sure the green
Power LED is
flashing on the CO
Detector for normal
operation
o Press and hold the
Test/Hush until the
unit beeps two (2)
times (approximately
five seconds) and
then release button
o You will hear four (4)
quick beeps from the
End-to-End Testing
For each device:
Keypad LCD will display:
<CO Device Name> -
CO Detected
(For example, “Master
Bedroom– CO
Detected”)
Keypad LCD will display:
Carbon Monoxide (CO)
Alarm Sent
Keypad LCD will
Display: Alarm – Enter
PIN to Cancel
Keypad LCD will display:
Alarm Canceled
Keypad LCD will display:
Enter PIN to Clear
A CO alarm has
been sent to AT&T
Digital Life Central
Monitoring Center
with no action
required