ACTA 4000 User Guide Programming ACTA
9836 4171 01 2008-12 43 (136)
Tightening
In the tightening interface dialog box, options regarding the tightening operations are set.
1 Default torque unit
In Basic ACTA, this sets the units for the torque.
Options: Nm, ozf.in, lbf.in, lbf.ft, kgf.m, kgf.cm, and Ncm.
In QC and AA ACTA: This setting is used in Quick Programming.
2 Default pulses unit
In Basic ACTA, this sets the units for the pulse.
Options: Number of and Hz.
In QC and AA ACTA: This setting is used in Quick Programming.
3 Buzzer
Allows you to set/select the functionality of the buzzer signal
Options: Off, Each tightening operation, Nok tightening, Batch complete, New
tool, Torque > min.
Nok tightening means that the buzzer is triggered if the tightening value is outside
the limits programmed in Statistical setup under Program menu block.
(
Prog>Statistical setup>torque/angle/pulses).
Torque > min means that the buzzer is triggered when the torque during a
tightening operation rises above the torque min. limit (
Prog>Statistical
setup>Torque>Torque Min
).
4 Date
Here you input the current date manually. Note: This is updated automatically
when connecting to ToolsTalk QAT.
5 Time
Here you input the current time manually. Note: This is updated automatically
when connecting to ToolsTalk QAT.
6 Torque value
Allows you to set the number of digits displayed in the torque value. You can
choose between 3, 4 or 5 digits.
7 Routing
Allows ACTA to select the next tool in your Database automatically when you
have completed a batch with the current tool.
Options: Off, Tool, Job
See the
About Routing section below for details on routing.