Minimum
setting
Factory
setting
Maximum
setting
GA VSD 200 psi (13.8 bar) Full-Feature
compressor
bar(e) 9.0 13.5 13.8
GA VSD 200 psi Full-Feature compressor psig 131 196 200
GA VSD 200 psi (13.8 bar) Full-Feature
compressor with DD filter
bar(e) 6.0 10.4 13.6
GA VSD 14 bar (203 psi) Full-Feature
compressor with DD filter
psig 87 150 197
GA VSD 14 bar Pack compressor bar(e) 9.0 13.5 14.0
GA VSD 14 bar (203 psi) Pack compressor psig 131 196 203
GA VSD 14 bar Full-Feature compressor bar(e) 9.0 13.5 13.8
GA VSD 14 bar (203 psi) Full-Feature
compressor
psig 131 196 200
GA VSD 14 bar Full-Feature compressor
with DD filter
bar(e) 6.0 10.4 13.6
GA VSD 14 bar (203 psi) Full-Feature
compressor with DD filter
psig 87 150 197
Indirect stop level bar 0.1 0.3 1.5
Indirect stop level psi 1.45 4.4 21.8
Direct stop level bar 0.1 1 1.5
Direct stop level psi 1.45 14.5 21.8
Proportional band % 10 15 20
Integration time sec 1 10 20
Minimum motor speed rpm 600 600 1500
Maximum rpm reduction % 75 100 100
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Minimum stop time: sec 0 15 255
Permissive start time: sec 0 30 255
Power recovery time (ARAVF) sec 15 15 3600
Restart delay sec 0 3 255
Communication time-out sec 10 20 60
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor outlet temperature:
Shut-down warning level ˚C 20 66 80
Shut-down warning level ˚F 68 151 176