Minimum
setting
Factory
setting
Maximum
setting
Shut-down warning level ˚C 0 120 120
Shut-down warning level ˚F 32 248 248
Shut-down level ˚C 0 120 120
Shut-down level ˚F 32 248 248
Delay at signal sec 0 1 3
dp oil separator (shut-down warning level) mbar -- 850 1000
dp oil separator (shut-down warning level) in WC -- 335 394
dp oil separator (shut-down level) mbar -- 1000 1000
dp oil separator (shut-down level) in WC -- 394 394
Delay at signal sec 5 60 255
On compressors with Energy Recovery
system also:
Temperature Energy Recovery water inlet,
warning level
°C 0 90 95
Temperature Energy Recovery water inlet,
warning level
°F 32 194 203
Temperature Energy Recovery water inlet,
shut-down level
°C 0 95 95
Temperature Energy Recovery water inlet,
shut-down level
°F 32 203 203
Delay at start sec 0 0 0
Delay at signal sec 0 5 10
Temperature Energy Recovery water outlet,
warning level
°C 0 90 95
Temperature Energy Recovery water outlet,
warning level
°F 32 194 203
Temperature Energy Recovery water outlet,
shut-down level
°C 0 95 95
Temperature Energy Recovery water outlet,
shut-down level
°F 32 203 203
Delay at start sec 0 0 0
Delay at signal sec 0 5 10
Service plans
Minimum
setting
Factory
setting
Maximum
setting
Service plan A (operating hours) hr See remark 4000 See remark
Service plan B (operating hours) hr See remark 8000 See remark
Service plan C (operating hours) hr See remark 16000 See remark
Service plan D (operating hours) hr See remark 24000 See remark
Service plan I (operating hours) hr See remark 2000 See remark
Instruction book
74 2920 1728 05