Installation Manual 5. Recovering CCE Image from USB
Version 2.0.5 49 Mediant 800 CCE & Mediant Server CCE
5 Recovering CCE Image from USB
The AudioCodes Mediant CCE Appliance is shipped with the Host server pre-installed;
however, in some cases customers may need to re-install or recover the CCE image.
This section describes the process for recovering the Mediant CCE Appliance (restore to
default).
Warning: All data will be removed from the hardware device during the recovery
process. During this process, a warning message is displayed, which prompts for
permission to continue before data is erased.
Note: It is important to use the USB dongle delivered with the appliance. If you create a
new USB dongle make sure it is labelled as ACSSetup”.
This section describes the recovery procedures:
Recovering AudioCodes Mediant Server CCE Appliance image (see below).
Recovering AudioCodes Mediant 800 CCE Appliance image (see Section 5.2 on page
52).
5.1 Recovering Mediant Server CCE Appliance Image
The procedure below describes how to install the software on the Mediant Server CCE
Appliance.
To install the software on the Mediant Server CCE Appliance:
1. Insert the Mediant CCE Appliance recovery USB Drive to the front USB port.
2. Power up the server.
3. When the HP Splash screen appears, press F11 for the Boot Menu.
Figure 5-1: HP Splash Screen

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing