Mediant CCE Appliances
4.1.7 Single Site with High Availability (HA) Compared to Multi-site
Deployments
The following table lists the differences between a single PSTN site with HA support and
multiple PSTN sites deployment (Multi-Site).
It is important that you set the different configuration values according to the rules
described in the table below:
Table 4-1: Single Site with High Availability (HA) and Multi-site Deployments
Item Single-Site with HA Multi-Site
Site Directory Requires the same shared folder
across instances.
Requires a different shared folder across
PSTN sites instances.
SIP Domains Domain names and order should be
the same across instances.
Domain names and order should be the
same across PSTN sites.
Site name Same Site Name across instances Different Site Name across PSTN sites.
Edge Certificate May use the same certificate for all
CCE in the site (may use wildcard).
May use the same certificate for all CCE
in all sites, the certificate should include
all sites SAN (may use wildcard).
VM password Recommended to use the same
password across instances.
May use different password across
PSTN sites.
Virtual machines
Internal IP
Different across instances. Different across PSTN sites.
Edge External
pool FQDN
Same across instances. Different across PSTN sites.
External IP Edge Different across instances. Different across PSTN sites.
PSTN GW
settings
Same gateway and order across
instances.
Different cross PSTN sites.
DNS record Add records with the same External
Access FQDNs and different IP
addresses.
Add records with different External
Access FQDNs and different IP
addresses.
Setup hybrid tenant
Set PeerDestination Set PeerDestination for fallback.

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing