28 AutoFarm GPS AutoSteer
Valve Type Installation Procedures
• Vehicles with an Open Center steering system.
• Pressure compensated steering systems without an Orbitrol Load Sense hose.
Valve Configuration
The AutoFarm valve has two internal plugs and orifices that must be configured to adjust the valve LS circuit for different
types of installations. For this installation you may use the factory default configuration and no changes are necessary. The
table below provides the recommended plug configuration for reference and troubleshooting purposes only.
Table 3-4 AutoSteer Valve Plug and Orifice Configuration
Type of Installation 13A 13B
Factory Default Configuration (valve as-delivered) PLUG OPEN
Closed Center Orbitrol – Conventional Load Sense PLUG OPEN
Closed Center Orbitrol – Dynamic Load Sense PLUG OPEN