EasyManua.ls Logo

Autronica Autro Safe BS-310 User Manual

Autronica Autro Safe BS-310
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Interactive Fire Alarm System
Release 3
Installation Handbook
Fire Alarm Control Panel, BS-310/320
Controller, BC-320
Protecting life, environment and property...
116-P-ASAFE-FA/DE, Rev. J, 2011-12-06

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Autronica Autro Safe BS-310 and is the answer not in the manual?

Autronica Autro Safe BS-310 Specifications

General IconGeneral
BrandAutronica
ModelAutro Safe BS-310
CategoryFire Alarms
LanguageEnglish

Summary

Introduction

About the Handbook

Explains the purpose and scope of the installation handbook for the AutroSafe system.

The Reader

Identifies the intended audience for the handbook, focusing on trained service personnel.

Reference Documentation

Lists other Autronica Fire and Security documents relevant to the system.

Environmental Requirements

Specifies the environmental conditions the equipment complies with, including temperature and protection.

Equipment List

Details the components that make up the AutroSafe Fire Alarm Control Panel and Controller.

Assembly Drawing

Provides a visual representation of how the internal components are assembled within the cabinet.

Internal Cable Connections

Introduction

Introduces the chapter on internal cable connections and system customization.

Before Connecting Cables

Emphasizes safety precautions, like ensuring power is off, before making connections.

Location of Fuses

Details the location and types of fuses used in the power supply and connection modules.

Shielding and Earthing

Explains the importance and methods for proper shielding and earthing of cables.

Power Supply and Battery Connections

Guides on connecting the mains power, batteries, and battery charging systems.

Connecting the Network Cables (AUTROLON)

Describes how to connect external and internal AUTROLON network cables.

Internal Cable Connections - Overview

Provides a general overview of internal cable routing and connections within the system.

Connections for Temperature Compensated Battery Charging Voltage

Details the connection of a temperature sensor for battery charging.

Installing I/O Modules

Introduction

Introduces the chapter on mounting and removing I/O modules for the system.

Front View of I/O Module

Shows the front panel layout and indicators of an I/O module.

Mounting / Removing I/O Modules

Provides step-by-step instructions for installing and uninstalling I/O modules.

Data Sheets - I/O Modules

Refers to user documentation for detailed data sheets on various I/O modules.

Power Module, BSS-310

Details the connections and indicators for the Power Module.

Communication Module, BSL-310

Outlines the connections for the Communication Module to other system components.

Loop Driver Module, BSD-310 / BSD-311

Describes the connections, indicators, and schematics for loop driver modules.

Output Module, Monitored, BSB-310

Explains the connections and schematics for monitored output modules.

Output Module, BSJ-310

Details the connections and schematics for output modules with open collector outputs.

Input Module, Monitored, BSE-310

Describes the connections, monitoring resistors, and schematics for monitored input modules.

Input Module, BSE-320

Outlines the connections for input modules with galvanic isolated inputs.

Larger Distributed Systems

AUTROLON Rings with Cable Lengths >1km

Discusses maximum cable lengths for AUTROLON rings and the need for boosters.

Limitations when using AUTROLON Boosters

Specifies limits for booster placement, number of panels, and total ring length.

Overview - Cable Connections

Illustrates the network topology for larger distributed AutroSafe systems.

Connections to the AUTROLON Booster BSL-325

Details the specific terminal connections for the AUTROLON Booster module.

Interfacing AutroMaster 5000

General

Provides a general overview of how AutroMaster 5000 interfaces with AutroSafe systems.

Connections - Overview

Explains the Ethernet connection requirements for interfacing with AutroMaster 5000 via HUB or direct connection.

General Application Details

Describes the general application of AutroMaster 5000 and its communication with AUTROLON rings.

Application with Twisted Pair Cabling

Illustrates system configuration using twisted pair cabling for network connections.

Application with Fibre Optic Cabling

Shows how fibre optic cabling is used for network connections in distributed systems.

Guidelines for the Installation and Addressing of Loop Units

Introduction

Introduces guidelines for installing and addressing loop units in the AutroSafe system.

Parameters Used During Configuration

Defines key parameters like Tag Name, Production Number, and Loop Sequence Index.

Which Parameters are Known?

Explains how cable layout affects the availability of configuration parameters.

Guidelines - Known Cable Layout

Provides steps for installation and configuration when the cable layout is known.

Guidelines - Unknown Cable Layout

Offers steps for installation and configuration when the cable layout is unknown.

Service and Maintenance

Introduction

Introduces the chapter on system service and maintenance procedures.

Monthly Maintenance

Lists the tasks to be performed during monthly checks of the AutroSafe system.

Annual Service and Maintenance

Details the procedures for annual system inspection, testing, and restarts.

Reader's Comments

Related product manuals