Do you have a question about the Autronica AutroGuard Multicriteria Protector V-430 Series and is the answer not in the manual?
Current Consumption (alarm) | 3 mA |
---|---|
Operating Temperature | -20°C to +70°C |
Humidity | 0% to 95% RH (non-condensing) |
Relative Humidity | 0% to 95% RH (non-condensing) |
Protection Class | II |
Certifications | EN 54-7, EN 54-17 |
Defines the handbook's scope, audience, and emphasizes manual reading.
Lists related documents and provides URL for downloading technical information.
Defines technical terms and abbreviations used in the handbook.
Details revisions made to the technical handbook over time.
Provides critical safety warnings, warranty disclaimers, and liability limitations.
Specifies intended use and highlights important installation/operation notices.
Covers general safety regulations, standards, and directives compliance.
Instructs on safe installation, maintenance, and warns against modifications.
Discusses environmental considerations, recycling, and disposal guidelines.
Provides a general description of the AutroGuard Multicriteria Protector and its base.
Explains how to order different variants (V-430, V-530, V-100, V-110/120) and accessories.
Information on marking and labeling of the protector and base.
Explains QR, Data Matrix codes, and tag holder usage for product identification.
Provides dimensional drawings of the protector and base variants.
Details technical specifications for the protector and its base.
Provides technical specifications for the integrated sounder.
Lists EN54-3 approved tones and their sound pressure levels.
Details sound pressure levels for various tones at different measurement angles.
Outlines current consumption for integrated VADs (white and red LEDs).
Details current consumption for VAD and sounder combined.
Describes basic functionality and the smoke detection chamber design.
Introduces DYFI3D for fire detection analysis and signature analysis.
Explains dynamic filtering for minimizing false alarms.
Describes sensitivity adaptation and protector operation classes.
Details heat response categories as per EN54-5.
Explains the self-test function and the cover detection feature.
Explains protector status signals and LED behavior.
States VAD compliance with EN54-23 and explains coverage volume.
Details coverage volume for ceiling-mounted VADs.
Describes open category VADs and VAD intensity settings.
Details flash rates and compares VAD intensities for white/red VADs.
Introduces audible devices, sound pressure levels, and sound/pulse patterns.
Emphasizes regulations and covers environmental/location requirements.
Provides guidance on area coverage and monitoring distances for detection.
Details current consumption of units for loop planning.
Describes cable entry options on the protector base.
Provides instructions for mounting the protector base.
Instructions for connecting loop cables, including requirements and methods.
Explains alignment marks for mounting the protector.
Step-by-step guide for mounting the protector onto the base.
Details how to lock and unlock the protector using a tool.
Instructions for removing the protector and retrofitting onto existing bases.
Explains labeling the base and the use of the protector cover.
Introduces preparation and lists required tools for configuration.
Presents methods (QR, label) for identifying protector serial numbers.
Guides on labeling bases and scanning loops with AS2000.
Details generating Excel files and merging tag names/serial numbers.
Instructions for AutroSafe tool usage and troubleshooting loop issues.
Introduces recommendations and provides settings for hotel rooms.
Offers configuration recommendations for apartments.
Recommends configurations for freezers, cold stores, and clean rooms.
Refers to a table overview of applications and settings.
Introduces AutroSafe configuration and specifies tool requirements.
Details settings for site configuration, including LED defaults.
Guides on adding system units like AutroGuard Protectors.
Explains how to set default properties for AutroGuard variants.
Describes how to set properties for multiple protectors simultaneously.
Details how to configure individual AutroGuard protector settings.
Emphasizes matching protector/base variants with configurations.
Introduces Autroprime configuration and specifies software requirements.
Covers global settings for sound patterns and VAD in Autroprime.
Details how to configure individual AutroGuard settings in Autroprime.
Explains the self-test function and recommends visual inspections.
Covers manual testing procedures, equipment, and auto test mode.
Details cleaning procedures and hot-swapping protectors.
Explains how to re-calibrate the cover detection sensor using two methods.
Describes the locking tool and QR code reader requirements.
Details diagnostic tools and the protector cover.
Describes the air duct sampling unit for smoke detection.
Details the stainless steel version of the air duct sampling unit.
Information about conduit boxes for mounting.
Describes removal tool and ground device for loop cables.
Recommends test gas and test tools for maintenance.
Provides UL certification and regulatory information for variants.