Interfacing AutroMaster_5000
Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE,
Rev. J, 2011-12-06,
Autronica Fire and Security AS
5.3.2 Application with Twisted Pair Cabling
AutroMaster 5000
(master)
AutroMaster 5000
(slave)
BS-320
BC-320
HUB
AUTROLON
RING 1
Detection
Loop
BN-300
BN-310
Alarm, Fault Warning
BSD-310
2K End Resistance
Note:
Make sure that connections are galvanically isolated.
BS-320
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz z er
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
BS-320
A
UTROLON
RING 2
BS-320
BC-320
BS-320
2K End Resistance
Detection
Loop
BN-310
BN-300
BSD-310
Alternative 2
Twisted Pair Cable
Maximum 90m
Twisted
Pair
Cable
Power
Fault
Self Verify
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
Power
Fault
Self Verify
BS-320
Alternative 2
Twisted Pair Cable
Maximum 90m
Alternative 2
Twisted Pair Cable
Maximum 90m

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autronica Autro Safe BS-310 and is the answer not in the manual?

Autronica Autro Safe BS-310 Specifications

General IconGeneral
BrandAutronica
ModelAutro Safe BS-310
CategoryFire Alarms
LanguageEnglish

Related product manuals