Interfacing AutroMaster_5000
Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE,
Rev. J, 2011-12-06,
Autronica Fire and Security AS
5.3.3 Application with Fibre Optic Cabling
Detail connection drawing
RX
TX
Converter
Fibre Optic
Maximum
1000-2000m
HUB
Twisted
Pair
Cable
RX
TX
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
987
6
54
3
21
Silence Bu zzer
Silence Sounders
Reset
More Alarms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
RX
TX
Converter
Fibre Optic
Maximum
1000-2000m
HUB
Twisted
Pair
Cable
RX
TX
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
987
6
54
3
21
Silence Bu zzer
Silence Sounders
Reset
More Alarms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
AutroMaster 5000
(master)
AutroMaster 5000
(slave)
BS-320
BC-320
HUB
A
UTROLON
RING 1
Detection
Loop
BN-300
BN-310
Alarm, Fault Warning
BSD-310
2K End Resistance
Note:
Make sure that connections are galvanically isolated.
Twisted
Pair
Cable
BS-320
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
BS-320
A
UTROLON
RING 2
BS-320
BC-320
BS-320
2K End Resistance
Detection
Loop
BN-310
BN-300
BSD-310
Twisted
Pair
Cable
Alternative 1
Fibre Optic
Maximum
1000-2000m
Alternative 1
Fibre Optic
Maximum
1000-2000m
Twisted
Pair
Cable
Converter
Converter
Converter
Twisted
Pair
Cable
Twisted
Pair
Cable
Converter
Alternative 1
Fibre Optic
Maximum
1000-2000m
Power
Fault
Self Verify
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabl ed
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buz ze r
Silence Sounder s
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
Power
Fire Brigade Msg
Fire Vent Activated
Fire Ext Activated
0
ALARM
?
C
98
7
654
3
21
Silence Buzzer
Silence Sounders
Reset
More Ala rms
Prewarning
Early Warning
System Fault
Function Disabled
Test
Fault
Self Verify
General Alarm
Power
Fault
Self Verify
BS-320
Converter
Converter