Note:
You must add the LSP server correctly to the Main Communication Manager Server.
2. If valid translations are not file synchronized to the LSP, do the following:
a. From a SAT session run from the primary controller, verify that the LSP node-name
and IP address are correctly entered.
b. Use the save translation lsp command to start the file synchronization
process.
c. Log in again to Avaya Aura
®
Communication Manager from the LSP and list either
stations or trunks.
d. Verify that the list of stations or trunks is valid.
3. Disconnect the Branch Gateway from the primary controller, ensuring that all telephones
are still connected or have network connectivity to the Branch Gateway.
4. Verify that calls can be made between local telephones using the locally connected outside
lines to the Branch Gateway.
Result
Note:
See also “Auto Fallback for H.248 Gateways” in Administering Network Connectivity on Avaya
Aura
®
Communication Manager and the Migrate H.248 MG to primary" screen command in
Avaya Aura
®
Communication Manager Screen Reference.
Important note regarding Spectre and Meltdown vulnerability and Release 7.1.3:
Note:
The G430/G450 Branch Gateways are not vulnerable to the Spectre and Meltdown hardware
issue. The processor used by the G430/G450 Branch Gateways is not included in the list of
processors identified to be impacted by the Spectre and Meltdown vulnerabilities.
However, an S8300D installed within the gateway that is upgraded to Release 7.1.3 may be
impacted as indicated below.
Note:
The introduction of Spectre and Meltdown fixes with 7.1.3 impacts the S8300D scalability
performances. A survivable remote configuration (Communication Manager LSP and Branch
Session Manager) with the Spectre and Meltdown fixes enabled can only now support 200
users with up to 500 BHCC traffic.
Since these fixes are enabled by default, consider whether configuration changes are in order
to plan an 7.1.3 upgrade.
The following options should be considered if higher capacity is required from the S8300D:
• Disabling the Spectre and Meltdown fixes on the S8300Ds enables the S8300D to deliver
the same level of capacity as with 7.1.2 and before.
• If disabling the fixes on the S8300D is not an option, plan to upgrade the embedded
server to the latest S8300E model.
Post-installation verification
July 2018 Deploying and Upgrading Avaya G430 Branch Gateway 60
Comments on this document? infodev@avaya.com