EasyManua.ls Logo

Avery Dennison AP5.4 Gen II - Head Strobes; Head Temperature; Foil Diameter; Dispensing Cycl

Avery Dennison AP5.4 Gen II
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP5.4 Gen II – AP5.6
99
Head strobes
AP5.4 AP5.6
Shows the counted head strobes, which are a measure for the service life of
the printhead. A strobe is counted for each line in which at least one dot ist
printed. Maximum value: 4 billions.
Head temperature
AP5.4 AP5.6
Shows the current printhead temperature in °C.
Foil diameter
AP5.4 AP5.6
Shows the calculated foil diameter: A measurement routine calculates the ac-
tual ribbon roll diameter with an exactness of 7.5%.
The parameter
SYSTEM PARAMETER > Foil end warning can be used to set a critical
foil roll diameter. If the foil roll diameter equals this value, a message appears
on the printer display.
P See parameter Foil end warning on page 68.
Dispensing cycl.
(Dispensing cycles)
AP5.4 AP5.6
¯ AP5.4/5.6: Dispenser version only.
Shows the number of dispensed labels.
Operation time
AP5.4 AP5.6
Shows the elapsed time since the last switch-on of the machine.

Table of Contents