134 DSView Installer/User Guide
c. In Label 1, type Test Configuration. All first-level custom fields for units will appear
under this heading in the side navigation bar.
d. In Label 2, type
Appliances and target devices. All second-level custom fields for units
will appear under this heading in the side navigation bar.
e. In Label 3, type
Manager. This custom field will not appear in the side navigation bar, but
may be displayed in the content area by clicking Customize and adding the field.
f. Click Save to save your changes.
Custom Field Labels will still appear in the side navigation bar because the administrator
has not yet defined any custom fields for units.
2. A DSR1021 switch has been configured on the system, but will need to go into a group named
Initial Configuration, since it has not yet been verified for the final configuration. The
administrator will associate the DSR1021 switch managed by John Smith to the custom fields
as follows:
a. From the side navigation bar, click Appliances. The Appliances - All window will open.
b. Click on a DSR1021 switch. The Unit Overview window will open. The side navigation
bar will include the name of the DSR1021 switch at the top and a list of items below it.
c. From the side navigation bar, click Properties.
d. From the side navigation bar, click Custom Fields. The Unit Custom Fields window will
open, including the custom field names you defined in step 1.
e. In the Test Configuration field, type
Initial Configuration.
f. In the Appliances and target devices field, type
DSR1021 Switches.
g. In the Manager field, type
John Smith.
h. Click Save to save the changes.
i. Click Close. The Appliance - All window will open. The side navigation bar will now
include Test Configuration instead of Custom Field Labels.
3. The test configuration will also include an EVR1500 environmental monitor that is managed
by Mary Jones. The EVR1500 environmental monitor has also not been verified for the final
configuration, so the administrator will include it in the Initial Configuration group.
a. From the Appliances - All window, click on an EVR1500 environmental monitor. The
Unit Overview window will open. The side navigation bar will include the name of the
EVR1500 environmental monitor at the top and a list of items below it.
b. From the side navigation bar, click Properties.
c. From the side navigation bar, click Custom Fields. The Unit Custom Fields window will
open, including the custom field names you defined in step 1.
d. In the Test Configuration field, type
Initial Configuration.
e. In the Appliances and target devices field, type
EVR1500 Environmental Monitors.
f. In the Manager field, type
Mary Jones.
g. Click Save to save the changes.