200 DSView Installer/User Guide
The Session Properties dialog box will appear.
2. Click the Terminal tab.
3. In the Terminal Type box, enter a value of up to 40 characters, beginning with a letter and
ending with a letter or digit. Valid characters are the letters A-Z, digits
0-9, forward slash,
dash, left parenthesis and right parenthesis. The terminal type must be entered in the Terminal
Type field exactly as shown in Table 7.4.
To change the linefeed settings:
1. Select Options - Session Properties from the menu bar.
-or-
Click the Session Settings icon in the toolbar.
The Session Properties dialog box will appear.
2. Click the Terminal tab.
3. When connecting to devices that do not insert a carriage return in incoming or outgoing data,
automatically inserting a line after each line of data can prevent overwriting data when a new
line is received.
If the New Line Mode - Inbound box is checked, an inbound carriage return from the device
will be treated as if both a carriage return and a linefeed were received. If not checked, a
linefeed is not added to an inbound carriage return.
If the New Line Mode - Outbound box is checked, an outbound carriage return to the device
will always be followed by a linefeed character. If not checked, a linefeed is not sent with a
carriage return. The default value is disabled for inbound and outbound.
To enable/disable line wrap:
1. Select Options - Session Properties from the menu bar.
-or-
Click the Session Settings icon in the toolbar.
Table 7.4: Terminal Emulation and Type
Terminal Emulation Terminal Type
VT52 DEC-VT52
VT100 DEC-VT100
VT100+ DEC-VT100
VT102 DEC-VT102
VT220 DEC-VT220
VT320 DEC-VT320