SENSOR PROGRAMMING
3.6.6. Adjust Switch Point
The AdjSPt option manually adjusts the value of the switch point threshold for the discrete output when the sensor is in Switch mode. The value
is adjustable within the sensor's range. This menu is not available when the sensor is in Window, Alarm, or Health mode.
Navigate: MENU > D_OUT > AdjSPt
Remote Input: Not available
Default: 50 mm
3.6.7. Mode
The Mode option sets the output to the desired mode.
Navigate:MENU > D_OUT > Mode
Remote Input: Available
Default: Wnd (Discrete Output is On while a target is detected between the SPt1 and SPt2 thresholds) mode
The following table describes the sensor modes.
Remote Input Instructions
1) Access the setup mode.
2) View the current mode.
3) Program the sensor.
Action Result
Five-pulse the remote input.
"TchSPt Teaching" displays while the sensor is being
taught.
TEACH Accepted
The new value displays on the second line of the
display, flashes, and the sensor returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 3, and
"RMT TCH" displays.
Mode Description
Alarm
Alarm Mode: The Discrete Output is Off while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is On.
This mode has no associated thresholds.
Health
Health Mode: The Discrete Output is On while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is Off.
This mode has no associated thresholds.
Swtch
Switch Mode: The Discrete Output is On while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is Off.
Swtch
Switch Mode: The Discrete Output is Off while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is On.
Wnd
Window Mode: The Discrete Output is On while a target is detected between the SPt1 and SPt2 thresholds. (Default)
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is Off.
Wnd
Window Mode: The Discrete Output is Off while a target is detected between the SPt1 and SPt2 thresholds.
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is On.
Action Result
Double-pulse the remote input. "REMOTE SETUP" displays.
Action Result
Double-pulse the remote input. The current mode displays.
TT
T
T
T
T
T
T
T
TT
T
TT
T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner LTF Series and is the answer not in the manual?

Banner LTF Series Specifications

General IconGeneral
BrandBanner
ModelLTF Series
CategorySecurity Sensors
LanguageEnglish

Related product manuals