P/N 133487 117
Banner Engineering Corp. Minneapolis, U.S.A.
www.bannerengineering.com Tel: 763.544.3164
SC22-3 Safety Controller
Instruction Manual
Appendix C
inputs in the current configuration that can be muted. Select Map
Inputs from the Mute Sensor Properties menu and press OK.
Using the up/down arrow buttons, select OS01 from the list of
inputs and press OK. The circle to the left of the OS01 fills in to
indicate that mute senor pair M1+M2 is mapped to OS01.
NOTE: In this case, the mute sensor pair is being mapped to
only OS01, but the mute sensor pair can be mapped to
more than one input.
Select Save and press OK to complete the input mapping
process.
Set the Mute Time Limit
The mute time limit defines the maximum amount of time an
input can be muted. From the Mute Sensor Properties menu,
select Set Mute Limit Timers and press OK.
When the next menu is displayed, press OK to display the Mute
Time Limit Enable menu.
Using the up/down arrow buttons, select Change Time and
press OK.
NOTE: If the box in front of Enable Time Limit is not checked,
select Enable Time Limit and press OK to enable the
time limit.
Change the mute time limit to 1 minute. Use the left/right arrows
to select the digit to be changed and the up/down arrows to
change the digit (0-9) and press OK.
At the Mute Time Limit Enable menu, select <Done> and press
OK.
At the Mute Sensor properties menu, select <Done> and press
OK to complete adding the mute sensor.
Safety Input: External Device Monitor EDM01
Circuit Type:
Single-Channel, 1 Terminal
Terminal: S17
Mapped to: SO1
Safety Input: External Device Monitor EDM02
Circuit Type:
Single-Channel, 1 Terminal
Terminal: S18
Mapped to: SO2
Safety Input: External Device Monitor EDM03
Circuit Type:
Single-Channel, 1 Terminal
Terminal: S19
Mapped to: SO3
All inputs have been added; press OK. When the Inputs menu
is displayed, press ESC to display the Edit Configuration menu
(see next page).