120 P/N 133487
Banner Engineering Corp. • Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
SC22-3 Safety Controller
Instruction Manual
Appendix C
Saving the Configuration
Up until now, the configuration changes have been stored in a
temporary memory location. To make the configuration changes
permanent, select Save Configuration and press OK.
NOTE: If you do not want to save the changes while at the Edit
Configuration menu, press ESC and select Yes when
asked if you want to exit without saving changes.
Once the configuration is saved, the display will return to the
Configuration Mode menu.
Confirming the Configuration
You will need to confirm the changes to the configuration before
it can be used in a safeguarding application. To confirm the
configuration, select Confirm Configuration and press OK.
The Confirm Configuration menu will appear.
To confirm you’ll need to review the safety-critical configurations
for the inputs, safety outputs, and the system settings. An
unchecked box in the Confirm Configuration menu indicates the
safety-critical settings have not yet been confirmed.
Confirm Configurations of Inputs
From the Confirm Configuration menu, select Inputs and press
OK.
The next menu lists all of the safety inputs in the configuration.
To confirm E-Stop ES01, select it and press OK.
The next series of menus lists the safety-critical configurations
for this input. Press OK after reviewing each setting.
Repeat the confirmation process for each of the inputs.
When all inputs have been confirmed, the display looks like this:
To continue confirming the configuration, select <Done> and
press OK.