36. Alarm sounds and screen displays:
EMERGENCY STOP PRESSED
(UNLOAD SIDE)
Unload side EMERGENCY STOP button is pressed.
1. Press Silence Buzzer or ACK touch pad to silence
alarm buzzer.
2. Turn EMERGENCY STOP button to disengage it.
3. Turn LOCK/UNLOCK/INIT selector switch to INIT position
and return washer to normal operation (selector returns
automatically from INIT to UNLOCK position when key is
released).
4. Press ABORT CYCLE or RESUME touch screen.
37. Alarm sounds and screen displays:
EMERGENCY CABLE ACTIVATED
EMERGENCY Cable inside washer is pulled.
1. Press Silence Buzzer or ACK touch pad to silence
alarm buzzer.
2. Check for obstruction inside chamber, remove obstruc-
tion if necessary.
3. Turn LOCK/UNLOCK/INIT selector switch to INIT position
and return washer to normal operation (selector returns
automatically from INIT to UNLOCK position when key is
released).
4. Press ABORT or RESUME touch screen.
* Service charges may be incurred. Consult your warranty for details.
Table 7-4. Troubleshooting Chart - Alarm and/or Printout (Cont’d)
ALARM MESSAGE POSSIBLE CAUSE AND CORRECTION