Oceanus
Page 18 2nd Edition, Rev. 0 Chg. 14
3.1.4 Oil Change Procedures
1. Run the compressor until it reaches normal operating temperature, then shut it off.
2. Remove the oil dipstick from oil filler tube.
3. While the oil is still warm, remove oil drain plug and drain oil into an appropriate container.
4. After oil has completely drained, reinstall oil drain plug and tighten.
5. Refill with 1.37 quarts (1.3 liters) of oil, through the oil filler tube.
6. Check oil level using the oil dipstick.
7. Oil level is correct if it is at the upper mark. See Figure 3-1
3.2 Intake Filter
3.2.1 Description
A dry micronic filter is used to filter the intake air. See Figure 3-2.
3.2.2 Maintenance
The filter cartridge must be changed at regular intervals.
1. Remove knurled nut (1) and take off plastic cap (2).
2. Replace Filter Cartridge with a new Filter Cartridge.
3. Inspect O-ring (4) and replace if damaged.
4. Replace plastic cap and tighten knurled nut
3.2.3 Telescopic Intake Tube
See Figure 3-2. The telescopic intake tube is inserted in the intake opening (5). This is necessary to
ensure clean intake air on gasoline engine driven compressor units.
Figure 3-2 Intake Filter
1. Knurled Nut
2. Plastic Cap
3. Micronic Filter Cartridge
4. O-ring
5. Intake Opening
1
2
3
4
5

Table of Contents