August 27, 2009 Page 57
5.2 P0 Purification System
5.2.1 Description
The P0 Purification System consists of a separator and a cartridge chamber. In the separator surrounding
the cartridge chamber, liquid oil and water particles are separated from the compressed air by a pipe noz-
zle. Residual oil and water particles are then removed by the filter cartridge and the air leaving the P0
Purification System is free of water, oil, taste and smell.
Figure 5-5 P0 Purification Chamber
1. Inlet Connection
2. Condensate Drain Connection
3. Condensate Drain Valve
4. Bleed Port
5. Bleed Valve
6. Pressure Maintaining Valve
7. Outlet Connection
8. Safety Valve
1
2
3
4
5
6
7
8

Table of Contents