RIGGING / DE-RIGGING
BG 25 / 2011 / 2254_BG25_en_0000498763_V01
7 - 22
7.6.2 Mounting Casing Oscillator *
NOTE
How to mount a casing oscillator to the machine is described in the
separate manual belonging to the casing oscillator in question.
Pass hoses from casing oscillator over
left and right crawler crossbeam up to
bulkheads "A".
A
BM779507.wmf
Stop the engine of the base machine.
Remove dust caps from hydraulic connections.
Mount the hydraulic couplings in compliance with the provided numbers.
Make electric connection of casing oscillator and base machine.
View "A":
Undercarriage seen from the rear. The identified couplings are found on the front side
of the two bulkheads.
BM779414.jpg
20 Oscillation [P]
21 Oscillation [R]
22 Unclamping
23 Clamping
24 Lowering
25 Lifting
28 Locking
29 Unlocking
30 Leak oil [T] (optional)
PST Pilotoil (optional)
E1 Electric connection (optional)
*) Not used in this version