START-UP / SHUT-DOWN
BG 25 / 2011 / 2254_BG25_en_0000498763_V01
6 - 4
6.1.4 Safety Tests before Starting to Work
WARNING!
Serious accident hazard!
Faulty safety devices are dangerous.
All equipped safety devices must be tested prior to starting to work, and
any faults found must be repaired by skilled personnel.
The equipment may be put to work only when all safety devices are in
proper working order.
Initial situation:
- Diesel engine is running
6.1.4.1 Checking the Emergency STOP
Press the Emergency STOP button.
All control elements must be out of function and the diesel engine comes to a stop.
6.1.4.2 Checking the Pilot Control Safety Stick
Move the safety stick of the pilot control to "OFF" position.
All hydraulic functions must be blocked. The diesel engine remains on.

Table of Contents