MAINTENANCE
BG 25 / 2011 / 2254_BG25_en_0000498763_V01
9 - 6
9.3.3 Work Equipment
Table Equipment
Components
Maintenance interval
Operation
10 h
daily
50 h
weekly
250 h
monthly
500 h
3 months
1000 h
yearly
2000 h
yearly
3000 h/
every
2 years
Note
Rotary drive
Rotary drive
- Clean
X
- Inspect for wear and damage
X
- Check for leakage
X
- Check magnetic bars for adhesion
of metal parts
X
- Check oil level
Main gear
X
Planetary gears
X
- Change oil
Main gear
X*
X
Planetary gears
X*
X
- Take oil sample and check oil
X
- Check if hollow shaft mounting
bolts are securely fastened
X*
X
- Check switch pressure
X
Nominal
value:
35-40 bar
- Change filter
Line filter
X*
X
Oil pre-cleaner
X*
X
- Lubricate oil seal
X
Kelly driver / guide flange / shock absorber
- Check springs, shock absorbers
and buffer rings for damage
X
- Check that the mounting bolts are
firm
X
- Check driver strips for wear
X
Cardan joint
- Check rubber buffers for
damage
X
- Check if bolts are secure
X
Crowd sledge
- Check sliding strips for wear
X
Kelly bar
- Inspect for wear and damage
X*
X
Drilling tool
- Clean and check for wear and
damage
X
CFA/FOW/DKS equipment **
- Lubricate concreting head
X
* Only during running-in period
** Not supplied with this version

Table of Contents