MAINTENANCE
BG 25 / 2011 / 2254_BG25_en_0000498763_V01
9 - 10
9.3.6 Optional Equipment
Optional equipment table
Components
Maintenance interval
Operation
10 h
daily
50 h
weekly
250 h
monthly
500 h
3 months
1000 h
yearly
2000 h
yearly
3000 h/
every
2 years
Note
Air conditioning
- Operate the air conditioning sys-
tem
X
2 - 3 weeks
- Clean air filters (optional)
X
- Clean condenser
X
Compressor Observe separate compressor manual!!
- Clean cooling ribs
X
- Clean suction air filter
X
- Replace suction air filter
X
- Clean lubricating oil filter
X
- Replace lubricating oil filter
X
- Change oil
X*
X
- Check maintenance unit
X
- Drain condensate on compressor,
maintenance unit, 70 l pressure
accumulator
X
after every
use
Oxidation-type catalytic converter
- Measure the counter pressure of
the exhausts treated by the CRT
system
X
Generator
Inspect for wear
and damage
Checking the Oil Level
Replace the breather filter
Check ISO meter
X
X
Before each use
Before each use
* Only during running-in period

Table of Contents