4.3
P1159
Setting the bias polarity of the keypad potentiometer. For further information see
ZP1158– from page 103.
P1160
Setting the gain of the keypad potentiometer. For further information see ZP1158– from
page 103.
P1161
For further information see ZP1158– from page 103.
P1162
This parameter sets the function of the AFM output 0 to +10 V
DC
(ACM is common), see
also ZP1163– from page 109.
P1159
Bedienfeld Potentiometer Offset Polarität 0 to 1
EE Keypad potentiometer bias polarity 0
ON BM_u_KeypadPotentiometerBiasPolarity 1:1
Value Meaning
0 Positive bias
1 Negative bias
P1160
Bedienfeld Potentiometer Verstärkung 0.1 to 100.0 %
EE Keypad potentiometer gain 100.0 %
ON BM_u_KeypadPotentiometerGain 1:1
P1161
Bedienfeld Potentiometer negativ AN/AUS 0 to 1
EE Keypad potentiometer negative enable/disable 0
STOP BM_u_KeypadPotentiometerEnable/Disable 1:1
Value Meaning
0 No negative bias command
1 Negative bias: REV motion enabled
P1162
Analoges Ausgangssignal 0 to 1
EE Analog output signal (AFM) 0
ON BM_u_AnalogOutputSignal 1:1
Value Meaning
0 Analog frequency meter (0 to maximum output frequency)
1 Analog current meter (0 to 250 % of rated current)