Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
119
of 208
4
P1187
Status for ramp function generator.
P1188
This parameter displays the frequency output of the ramp function generator.
P1189
The multi-function input terminals MI3 to MI5 or MI7 to MI12 (refer to ZP1091 to
ZP1093 and ZP1095 to ZP1100) are used to select one of the b maXX
®
1000 multi-
step speeds. The speeds (frequencies) are determined by ZP1189 to ZP1203, for fur-
ther information see ZFigure 24on page 78.
P1190
The multi-function input terminals MI3 to MI5 or MI7 to MI12 (refer to ZP1091 to
ZP1093 and ZP1095 to ZP1100) are used to select one of the b maXX
®
1000 multi-
step speeds. The speeds (frequencies) are determined by ZP1189 to ZP1203, for fur-
ther information see ZFigure 24on page 78.
P1187
Hochlaufgeber Status 0 to 65535
- Ramp function generator status 0
A BM_u_RFGStatus 1:1
Bit Meaning
0 to 3 reserved
4 1: RFG output is internally set to 0 (RFG inhibit)
5 1: RFG is stopped on the ramp (RFG stop)
6 1: RFG input is internally set to 0 (RFG zero)
7 1: Quickstop ramp is active (RFG quickstop)
8 1: Ramp-up is active
9 1: Ramp-down is active
11 ... 10 reserved
12 1: RFG output = RFG input (set value reached)
P1188
HLG Ausgang 0.00 to 600.00 Hz
- RFG output 0.00 Hz
A BM_u_RFGOutput 100:1
P1189
1. Stufengeschwindigkeit 0.00 to 600.00 Hz
EE 1st step speed frequency 0.00 Hz
ON BM_u_1StepSpeedFrequency 100:1 -
P1190
2. Stufengeschwindigkeit 0.00 to 600.00 Hz
EE 2nd step speed frequency 0.00 Hz
ON BM_u_2StepSpeedFrequency 100:1 -