Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
14
of 208
5 OPERATION ENABLEDSWITCHED ON
n Event:
m Command ’inhibit operation’ or
m Pulse enable input MI6 = Low
n Condition:
m Zero speed is reached or for „inhibit operation“ an immediate pulse inhibit has
been set
n Action:
m Drive inhibit is commenced (according to settings: braking or coasting to a
standstill)
6 SWITCHED ONREADY-TO-START
n Event:
m Command ’shut down’ or
m Pulse enable input MI6 = Low
n Action:
m Feed unit ’ready for use’-signal monitoring will be deactivated
7 READY-TO-STARTINHIBIT READY TO START
n Event:
m Command ’quickstop’ or
m Command ’inhibit voltage’ or
m Quickstop input = Low (default quickstop input MI5 = 23)
n Action:
m none
8 ENABLE OPERATIONSHUT DOWN DRIVE ACTIVE
n Event:
m Command ’Shut down
n Action:
m Shut down of drive is commenced (according to settings: braking or coasting
to a standstill)
9 OPERATION ENABLEDSWITCH-ON INHIBIT
n Event:
m Command ’inhibit voltage’
n Action:
m Drive operation is inhibited
10 SWITCH ONINHIBIT READY TO START
n Event:
m Command ’inhibit voltage’ or
m Command ’quickstop’ or
m Quickstop input = Low (default quickstop input MI5 = 23)
n Action:
m none