4.3
P2082
ZP2081 and ZP2082 are used to record the motor operation time. They can be
cleared by setting to 0 and time is less than 1 minute is not recorded.
P2100
This parameter displays the identity code (word 1) of the b maXX
®
1000. Identity code
(word 2) is displayed via parameter ZP2101.
Figure 64: Type code
P2082
Motorbetriebszeit (Tag) 0 to 1439
- Accumulative motor operation time (day) 0
A BM_u_AccumulMotorOperationTimeDay 1:1
P2100
Typenschlüssel (word 1) 1111 to 1999
- Identity code (word 1) 1xxx
A BM_u_IdentCodeWord1 1:1