Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
146
of 208
4.3
P2105
This parameter displays the user-defined unit (Uxxx).
P2106
This parameter displays the number of pulses on TRG terminal.
P2108
This parameter displays the DC link voltage in V
DC
.
P2109
This parameter displays the output voltage of the terminals U/T1, V/T2, W/T3 to the motor
in V
AC
.
P2110
Here the PID analog feedback signal value in % is displayed (after the multiplication by
gain), complete PID diagram see ZP1369.
P2111
This parameter displays the power factor angle in ° of the terminals U/T1, V/T2, W/T3 to
the motor.
P2105
Benutzerdefinierte Einheit 0 to 60000
- User-defined unit 0
A BM_u_UserDefinedUnit 1:1 -
P2106
Zähler Triggerimpulse 0 to 65535
- Trigger count value 0
A BM_u_TriggerCountValue 1:1 -
P2108
Zwischenkreis Spannung 0.0 to 1000.0 V
- DC link voltage 0.0 V
A BM_u_DCLinkVoltage 10:1 -
P2109
Ausgangsspannung 0.0 to 1000.0 V
- Output voltage 0.0 V
A BM_u_OutputVoltage 10:1 -
P2110
PID Rückführung 0.00 to 327.67 %
- PID feedback 0.00 %
A BM_u_PIDFeedback 100:1 -
P2111
Leistungsfaktor Winkel 0.0 to 99.9 °
- Power factor angle 0.0 °
A BM_u_PowerFactorAngle 10:1 -