Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
44
of 208
4.3
P0558
This parameter defines in addition to ZP0001 the hardware version of the b maXX
®
1000 if the hardware was changed. 0 is an unknown hardware version.
P0800
This parameter determines the control method of the b maXX
®
1000.
P0801
This parameter set the master frequency command source of the b maXX
®
1000.
The factory setting for master frequency command is 5 (digital keypad is optional).
Setting 2:
use the ACI/AVI switch on the AC motor drive to select ACI or AVI2. When setting to AVI,
AVI2 is indicated.
When the b maXX
®
1000 is controlled by external terminal, please refer to ZP0805 for
details.
The first/second frequency/operation command is enabled/disabled by multi function in-
put terminals. Please refer to ZP1091 to ZP1094.
P0558
Controller Hardware-Version 0 to 65535
- Controller hardware version 1
A BM_u_ControllerHardwareVersion 1:1 -
P0800
Regelungsart 0 to 1
EE Control method 0
STOP BM_u_ControlMethod 1:1 -
Value Meaning
0 V/f control
1 Vector control
P0801
Quelle der ersten Hauptfrequenzvorgabe 1 to 225
EE Source of first master frequency command 5
STOP BM_u_SourceFirstMasterFrequComm 1:1 -
Value Meaning
255 Digital terminal 15 fixed set value
0 Digital keypad UP/DOWN keys or multi-function inputs UP/DOWN.
Last used frequency saved (digital keypad is optional).
1 0 to +10V from AVI
2 4 to 20mA from ACI or 0 to +10V from AVI2
3 ProDrive communication interface
4 Digital keypad potentiometer
5 CANopen