Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
45
of 208
4
P0802
The factory setting for source or first operation command is 2.
When the b maXX
®
1000 is controlled by an external terminal, please refer to ZP0805–
/ZP1090– for details.
* digital keypad is optional
P0802
Quelle des ersten Betriebskommandos 1 to 5
EE Source of first operation command 5
STOP BM_u_SourceFirstOperComm 1:1 -
Value Meaning
0 by digital keypad *
1 by external terminals, keypad STOP enabled *
2 by external terminals, keypad STOP disabled *
3 by ProDrive communication interface, keypad STOP enabled *
4 by ProDrive communication interface, keypad STOP disabled *
5 by CANopen
NOTE
Value 0, 1 and 2 needs the digital input PULSE ENABLE (input MI6).
Value 3, 4 and 5 needs the digital input PULSE ENABLE (input MI6) and QUICKSTOP (de-
fault multi function input MI5).