Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
69
of 208
4
P1004
Also see ZDevice managementfrom page 70.
This parameter determines the drive reaction in status quickstop. The reaction which was
set is always valid for the digital input ’quickstop’ and according to setting also for the
command quickstop. Default digital input is multi function input MI5.
For the command ’Quickstop’“ a separate reaction can be set via parameter ZP1009 or
the setting „Same reaction for command and digital input“ can be selected. If another re-
action as that for the digital input is selected for the command Quickstop, then the digital
input has higher priority. The value = 0 (inhibit pulses) has a higher priority to other values.
The speed controller must be sufficiently parameterized for a correct functioning of the
braking operations at the quickstop- or deceleration ramp.
At the settings 5 to 7after the braking operation the drive remains in the status QUICK-
STOP ACTIVE and again can be enabled.
P1005
Also see ZDevice managementfrom page 70.
This parameter determines the drive reaction at transition of status OPERATION EN-
ABLED towards READY FOR SWITCH ON (in the status machine of unit control).
The speed controller must be sufficiently parameterized for a correct functioning of the
brake operations at the quickstop- or deceleration ramp.
P1004
Schnellhalt Reaktion (Hardware) 0 to 7
EE QUICKSTOP reaction code (Hardware) 0
STOP BM_u_QuickstopCodeHardware 1:1 -
Value Meaning
0 Inhibit pulse
1 Braking operation at the deceleration time
2 Braking operation at the quickstop time
3 Braking operation at the deceleration automatic time
4 Inhibit pulses and remaining in status QUICKSTOP ACTIVE
5 Braking operation at the deceleration ramp and remaining in status QUICKSTOP ACTIVE
6 Braking operation at the quickstop time and remaining in status QUICKSTOP ACTIVE
7 Braking operation at the voltage limit and remaining in status QUICKSTOP ACTIVE
P1005
STILLSETZEN-Reaktion 0 to 3
EE SHUTDOWN reaction code 0
STOP BM_u_ShutdownCode 1:1 -
Reaction code Meaning
0 Inhibit drive function
1 Braking operation at the deceleration time by ramp function generator
2 Braking operation at the quickstop time by ZP1174
3 Braking operation at the deceleration automatic time